Why is it difficult to switch large-diameter valves? How to solve the problem?

Editor:嘉興美克斯閥門有限公司 │ Release Time:2022-01-12 

Among users who use large-diameter globe valves on a daily basis, they often report a problem that large-diameter globe valves are often difficult to close when they are used in media with a relatively large pressure difference, such as steam, high-pressure water, etc. When closing with force, it is always found that there will be leakage, and it is difficult to close tightly. The reason for this problem is caused by the structural design of the valve and the insufficient output torque of the human limit level.


Analysis of the Difficulty in Switching Large Diameter Valves


The average adult's horizontal limit output force is 60-90kg, depending on different physiques.


Generally, the flow direction of the globe valve is designed to be low in and high out. When a person closes the valve, the human body pushes the handwheel to rotate horizontally, so that the valve flap moves downward to realize the closing. At this time, it is necessary to overcome the combination of three forces, namely :


1) Axial thrust force Fa;


2) Friction force Fb between packing and valve stem;


3) The friction force Fc between the valve stem and the valve disc core


The sum of moments is ∑M=(Fa+Fb+Fc)R


It can be seen that the larger the diameter, the greater the axial thrust force. When it is close to the closed state, the axial thrust force is almost close to the actual pressure of the pipe network (because when it is closed, P1-P2≈P1, P2=0)


For example, a DN200 caliber globe valve is used on a 10bar steam pipe, only the first closing axial thrust Fa=10×πr2=3140kg, and the horizontal circular force required for closing is close to the horizontal circular force that normal human bodies can output. force limit, so it is very difficult for one person to fully close the valve under this condition.


Of course, some factories recommend installing such valves in reverse, which solves the problem of being difficult to close, but there is also the problem that it is difficult to open after closing.


Analysis of the Causes of Internal Leakage of Large Diameter Globe Valves


Large-diameter globe valves are generally used in boiler outlet, main cylinder, steam main and other positions. These positions have the following problems:


1) Generally, the pressure difference at the boiler outlet is relatively large, so the steam flow rate is also larger, and the erosion damage to the sealing surface is also larger. In addition, the combustion efficiency of the boiler cannot be 100%, which will cause the steam at the outlet of the boiler to have a large water content, which will easily cause cavitation and cavitation damage to the valve sealing surface.


2) For the shut-off valve near the boiler outlet and the sub-cylinder, because the steam that has just come out of the boiler has intermittent superheating phenomenon, in the process of its saturation, if the softening treatment of the boiler water is not very good, part of the acid is often precipitated Alkali substances will cause corrosion and erosion to the sealing surface; some crystallizable substances may also adhere to the valve sealing surface and crystallize, resulting in the valve not being able to be tightly sealed.


3) For the inlet and outlet valves of the sub-cylinders, the steam consumption after the valve is large and sometimes small due to production requirements and other reasons. The valve sealing surface causes erosion, cavitation and other damage.


4) Generally, when a large-diameter pipeline is opened, the pipeline needs to be preheated, and the preheating process generally requires a small flow of steam to pass through, so that the pipeline can be heated slowly and evenly to a certain extent before the stop valve can be fully opened to avoid causing the pipeline to rapidly Excessive expansion caused by heating up and damage to some connection parts. However, in this process, the valve opening is often very small, which causes the erosion rate to be far greater than the normal use effect, and seriously reduces the service life of the valve sealing surface.


Solutions to Difficulties in Switching Large Diameter Globe Valves


1) First of all, it is recommended to choose a bellows-sealed globe valve, which avoids the influence of the frictional resistance of the plunger valve and the packing valve, and makes the switch easier.


2) The valve core and seat must be made of materials with good erosion resistance and wear resistance, such as Stellite carbide.


3) It is recommended to adopt a double valve disc structure, which will not cause excessive erosion due to the small opening, which will affect the service life and sealing effect.


主站蜘蛛池模板: 在线播放无码后入内射少妇 | 国产精品自在线拍国产电 | 中文字幕字幕无码乱码在线 | 码亚洲中文无码av在线 | 国产熟睡乱子伦视频 | 国产精品中文字幕在线观看 | 国产99久久九九精品无码免费 | 999精品国产人妻无码系列久久 | 精品亚洲aⅴ无码午夜在线 精品亚洲a∨无码专区毛片 | 久久久国产精品免费A片3D | 日韩人妻少妇一区二区三区 | 黄色一级片免费观看 | 国产精品视频一区视频二区 | 久久国产乱子伦视频无卡顿 | 久久在精品线影院精品国产 | 日日噜噜夜夜狠狠久久aⅴ 日日噜噜夜夜狠狠视频buoke | 日韩一区二区三区免费视频 | 少妇人妻偷人精品 | 国产在线精品一区二区三区不 | 欧美日韩免费r | 无码孕妇孕交在线观看 | 久久精品一区二区三区不卡牛牛 | 日本视频免费高清一本18 | 久久久久99精品成人网站 | 国产精品一区二区三区四区五区 | 免费又黄又爽A片免费看 | 精品免费国产大片wwwwwwww | 中文字幕肉感巨大的乳专区 | 日本mv在线天堂不卡 | 久久久久亚洲av片无码v | 中文字幕一区二区精品区 | xxx波多野结衣xxxm | 美女国内精品自产拍在线播放 | 狠狠婷婷爱综合狠狠婷婷 | 久久久久久极精品久久久 | 日本一大免费高清杳蕉 | 亚洲国产日韩制服在线观看 | 精品熟女婷婷久久av | 亚洲高清国产拍精品动图 | 日韩免费一区二区三级片 | 午夜一区二区三区 |